Description
1、Premium Material: Wind speed monitoring sensor is made of premium ABS material with high strength, low startup wind speed and long service life. Stable performance and strong stability.
2、Anti Interference: Wind speed monitoring sensor has strong anti interference ability, IP64 waterproof design, compact and lightweight, easy to carry and assemble.
3、Outlet Mode: Anemometer sensor is compatible with two outlet modes, bottom outlet and side outlet. Easy to connect, save time and energy. Applicable to weather stations, industry and agriculture.
4、Strong Pressure Resistance: Wind speed detector has strong pressure resistance, suitable for all kinds of harsh environments and strong wind resistance. Enjoying 360 degree wind speed measurement and low consumption.
5、Equipped with Extension Cord: The extension cord is 0.8 meters long at the connection, and the interface has a sealing gasket design, which is sturdy and waterproof.
1 x Wind Speed Monitoring Sensor
Item Type: Wind Speed Monitoring SensorMaterial: ABSProduct Size: Approx. 158x180x70mm /
6.2x
7.1x
2.8inSupply Voltage: DC5VCommunicating Type: RS485 (Default for Modbus Protocol)Measuring Range: Wind Speed 0‑45m/sExtension Line Length At Connection:
0.8 Meters/
2.6ftAccuracy: ± (
0.5+
0.02V) M/s (V Represents The Real Time Wind Speed Value)Resolution:
0.1m/sStart Up Wind Speed: ≤
0.8m/sMaximum Power Consumption:
0.48WLoad Capacity: DC12V Power Supply, Current Type Output Impedance ≤ 350ΩDC24V Power Supply, Current Type Output Impedance ≤ 900Ω, Voltage Type Output Impedance ≥ 1KΩOperating Environment: Temperature ‑35℃ to 60℃, Humidity ≤
100.0% RH Without CondensationProtecting Grade: IP64Widely Used In: Greenhouse, Environmental Protecting, Ships, Docks, Breeding, Advertising Gates, Meteorology, Marine, Environment, Airports, Ports, Laboratories, Industry and Agriculture and Transportation and Other Environments of Wind Speed Measurement.Note about the sensor communicating protocol:First, if you are using a single sensor connected to the computer to read data directly, it is recommended to use the company's private protocol (see page 3), you can visualize the data in ASCII code (hex send, non hex receive);Second, if you are a multi sensor interconnection with PLC, configuration or programmable collector, it is recommended to use the standard for ModBus RTU protocol.Third, if there is no special requirements, the sensor parameters in the device address default 1, baud rate = 9600, the protocol for ModBus RTU.Standard for ModBus RTU protocol:Serial Port Format:Data bit 8 bits, stop bit 1 bit, parity bit None, default baud rate 9600bps, serial debugging software set to hex send and receive, two communicating intervals of at least 500ms or more, CRC in the specification for the parity bit, 2 bytes. The device address is 1 by default.For Modbus CRC checksum steps :
1. Preset the 16 bit register to hexadecimal FFFF, call this register as CRC register;
2. Isolate the first 8 bit data with the lower bit of the CRC register and put the result in the CRC register;
3. Check the lowest bit by shifting the contents of the register one bit to the right (towards the lower bit) and filling the highest bit with a 0;
4. If the lowest bit is 0: repeat step 3 (shift again) if the lowest bit is 1: the CRC register is iso orthogonal to the polynomial A001 (1010 0000 0000 0001);
5. Repeat steps 3 and 4 until it is shifted right 8 times so that the entire 8 bit data is all processed;
6. Repeating steps 2 through 5 for the next 8 bit data;
7. The last CRC register obtained is the CRC code (the CRC code obtained is low before high after).Wiring method (wire sequence respectively):Red: Power positiveBlack: A+Yellow: B-Green: Power negativeDistribution Diameter: 63mm/
2.5inInstallation hole diameter:
3.2mm/
0.13inAerial plug diameter: 15mm/
0.6in (it is recommended to reserve 25mm/
1.0in for easy wiring, first wiring, then install the fixed sensor)Troubleshooting:
1. The wind blade does not rotate properly and has a large hysteresis. There is foreign matter or jammed in the bearing due to long term use. Please send the sensor back to the company for processing;
2. Instrument display value is not correct when RS485 output. Possible wiring problems or communicating serial port failure to obtain the correct data. Please check whether the wiring is correct and firm, whether the serial port is occupied, and whether the serial port setting is correct.
-
Fruugo ID:
355120980-771962316
-
EAN:
9317843698792
Product Safety Information
Please see the product safety information specific to this product outlined below
The following information is provided by the independent third-party retailer selling this product.
Safety Warnings:
WARNING: Opening and/or repairing your device may result in risk of electric shock, damage to the device, fire and personal injury, and other hazards. We recommend that you seek professional assistance for device repairs and exercise caution when repairing your device yourself.