Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

HUF230,290.00
FREE Shipping

Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

Sold by:

Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

RRP: HUF460,490.00
Price: HUF230,290.00
You save: HUF230,200.00 (49%)
Sold by:
HUF230,290.00
FREE Shipping

In stock

We accept the following payment methods

Description

AC3000 digital manifold is a professional  instrument for installation, testing and maintenance of refrigeration equipment such as air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements ( with optional dual temperature probes ), a 32-bit digital processor and a large LCD in one easy-to-use instrument with the following main functions. 1.Pressure and Saturation Temperature. 2.Vacuum Operation. 3.Pressure Leak Test with recording. 4.Direct T1 T2 Temperature, Real-time Super heat and Sub cooling Simultaneously Display with Optional Two Clamp-on Temperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. 6.Automatic Multi-unit Pressure Conversion. 7.Automatic Temperature ℃/℉ Conversion. It is the right one you have to do the job right. Pressure Measuring: 1. Turn off the blue valve and red valve. 2. Turn on the instrument. Then verify that LCD displays the status of the pressure test.If not,press the function button to switch it. 3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero. 4. Press R+/ R- buttons , Unit button and ℃/℉ button to select tested refrigerant and reading display respectively. 5. If the clamp-on temperature probes have been connected to the instrument, the real-time temperature will be displayed.If not, no display of it. 6. Connect the instrument to the refrigeration system according to the chart below. 7. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. 8. When the refrigeration system stops, turn on the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. 9. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. 10. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. 11. Shut down the refrigeration system,make sure all valves are turned off , then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. Vacuum Operation: 1. Turn off the blue valve and red valve. 2. Power on the instrument. Then make sure the LCD displays vacuum test status.If not, press the Function button to switch it. 3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero 4. Press the unit button to adjust the reading unit. 5. Connect the instrument to the refrigeration system.(Connected clamp-on temperature probes will not affect the operation.) 6. Turn on the blue valve and red valve, and start the vacuum pump. 7. After the vacuum operation is completed,turn off the blue valve and red valve, then shut the vacuum pump. At this time,pressure leak test mode can be used to check leakage in the system ( Please refer to Pressure Leak Test). Pressure Leak Test: 1. The instrument is powered on with the blue and red valves turned off. 2. Press the Function button to pressure leak test mode.
  • Fruugo ID: 184331743-393621310
  • EAN: 6264607529348

Product Safety Information

Please see the product safety information specific to this product outlined below

The following information is provided by the independent third-party retailer selling this product.

Safety Warnings: Keep out of reach of children under 36 months. Contains small parts that may present a choking hazard. Adult supervision required Please read and retain these instructions for future reference Remove all packaging before giving to children Keep away from fire and direct heat sources

Delivery & Returns

Dispatched within 2 days

  • STANDARD: FREE - Delivery between Mon 13 October 2025–Thu 30 October 2025 - FREE

Shipping from United States.

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy

Product Compliance Details

Please see the compliance information specific to this product outlined below.

The following information is provided by the independent third-party retailer selling this product.

Manufacturer
The following information outlines the contact details for the manufacturer of the relevant product sold on Fruugo.

  • Ebox
  • Ebox Inc
  • Central Ave, Chino,CA,USA
  • Chino
  • US
  • 91710
  • f.help@ebox-inc.com
  • 805 539 4494
  • https://www.ebox-inc.com

Responsible Person in the EU
The following information outlines the contact information for the responsible person in the EU. The responsible person is the designated economic operator based in the EU who is responsible for the compliance obligations relating to the relevant product sold into the European Union.

  • Axitera GmbH
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt a. Main,
  • Hessen, Germany
  • Frankfurt am Main
  • DE
  • 60486
  • successservice3@gmail.com
  • (+49) 6934873848